THREE PHASES · ONE TIMELINE
OED timeline: 2026 / 2027 / 2028
Which facility, by when, how many devices? We consolidated the three phases in the Ministry guide into one table. The same facility can meet different thresholds at different stages.
High-footfall locations
Smaller facilities
Broad network
The same facility can appear in more than one phase: for example, a workplace enters scope at 500+ employees in 2026, 200+ in 2027 and 100+ in 2028.
Days to the first deadline
31 December 2026 · 23:59 (TRT)
First deadline: 31.12.2026
2026 · High-footfall locations
Airports, shopping malls, stadiums, workplaces with 500+ employees, 500+ bed facilities and public transport.
| Location / facility | Threshold | Minimum device rule |
|---|---|---|
| Shopping malls | Malls with sales area above 5,000 m² | At least 1 per 10,000 m²; at least 1 below 10,000 m² |
| Event venues | Events with 1,000+ participants | At least 1 per 1,000 participants |
| Fitness gyms | Gyms above 800 m² licensed area | Single floor: at least 1 · Multi-floor above 2,000 m²: at least 2 |
| Airports | Passenger service areas | At least 1 + 1 per 10,000 m² + at least 1 per floor |
| Workplaces and campuses | 500+ employees (2026), 200+ (2027), 100+ (2028) | At least 1 per 1,000 employees; campus area is assessed separately |
| City squares | Central squares designated by metropolitan municipalities | At least 1 per 50,000 m² |
| Hotels and student dormitories | 500+ beds (2026), 100+ beds (2027) | 2026: 1 per 500 beds · 2027: at least 1 per facility |
| Rail stations, terminals and trains | Passenger rail transport | Terminal: at least 1 + 1 per 10,000 m² + 1 per floor · Train: 1 per train · Station: at least 1 |
| Stadiums and sports venues | Above 10,000 m² / 10,000 seats (2026); above 5,000 m² / 1,000 seats (2027) | At least 1 + 1 per 5,000 m² + 1 per 10,000 stadium seats + 1 per stand |
| Intercity bus terminals | Terminals in provincial centres and districts of 100,000+ population | At least 1 + 1 per 50 platforms + 1 per 20,000 m² |
| Passenger ships | Vessels carrying 100+ passengers | At least 1 per vessel |
| Passenger aircraft | Aircraft carrying passengers | At least 1 per aircraft |
First deadline: 31.12.2027
2027 · Smaller facilities
Accommodation and dorms with 100+ beds, workplaces with 200+ employees, large places of worship, sports venues above 5,000 m²/1,000 seats, TOHM/SEM.
| Location / facility | Threshold | Minimum device rule |
|---|---|---|
| Hotels and student dormitories | Facilities above 100 beds; dormitories with 100+ capacity | At least 1 per facility |
| Workplaces and campuses | 200+ employees at the same time | At least 1 per workplace; campus area is assessed separately |
| Central large places of worship | 10,000 m² and above | At least 1 per 10,000 m² |
| Sports venues, halls and stadiums | Above 5,000 m²; stadiums above 1,000 seats | At least 1 |
| TOHM and SEM centres | Türkiye Olympic Preparation Centres and Athlete Training Centres | At least 1 per centre |
First deadline: 31.12.2028
2028 · Broad network
Fuel stations and workplaces with 100+ employees.
| Location / facility | Threshold | Minimum device rule |
|---|---|---|
| Fuel stations | All fuel stations | At least 1 per station |
| Workplaces and campuses | 100+ employees at the same time | At least 1 per workplace; campus area is assessed separately |
Calculate your deadline and device count
This table summarises section 3.1 of the OED Guide (17.04.2026). The line for your facility type applies.