REGULATION · TIMELINE · SCOPE
OED regulation hub
The Regulation, the Ministry guide and the OED-Net process in one place. Every factual section links to its official source; the official text prevails.
Why now?
The Regulation was published on 9 December 2025 and entered into force on 1 January 2026. The guide brings the first mandatory locations into scope by 31 December 2026, starting with high-footfall sites such as shopping malls, airports, workplaces with 500+ employees and facilities with 500+ beds.
What does the Regulation require from a device?
- Portable, fully automatic device that analyses heart rhythm through pads and identifies shockable rhythms.
- Registered as a medical device in the Ministry’s Product Tracking System (ÜTS).
- Voice prompts in at least Turkish and English.
- Ability to transmit readiness, periodic test, battery, movement, location and ECG data to OED-Net.
- Supply from a company holding a medical device sales centre certificate, with a ÜTS unit notification.
Kaynak: Yönetmelik m.5, m.8; OED Rehberi bölüm 2.2 ve 3.1.
Scope and phases
Location categories and minimum device formulas from the guide. The same facility can meet different thresholds at different stages.
| Location / facility | Phase | Minimum rule |
|---|---|---|
| Shopping malls | 2026 | At least 1 per 10,000 m²; at least 1 below 10,000 m² |
| Event venues | 2026 | At least 1 per 1,000 participants |
| Fitness gyms | 2026 | Single floor: at least 1 · Multi-floor above 2,000 m²: at least 2 |
| Airports | 2026 | At least 1 + 1 per 10,000 m² + at least 1 per floor |
| Workplaces and campuses | 2026 | At least 1 per 1,000 employees; campus area is assessed separately |
| City squares | 2026 | At least 1 per 50,000 m² |
| Hotels and student dormitories | 2026 | 2026: 1 per 500 beds · 2027: at least 1 per facility |
| Rail stations, terminals and trains | 2026 | Terminal: at least 1 + 1 per 10,000 m² + 1 per floor · Train: 1 per train · Station: at least 1 |
| Stadiums and sports venues | 2026 | At least 1 + 1 per 5,000 m² + 1 per 10,000 stadium seats + 1 per stand |
| Intercity bus terminals | 2026 | At least 1 + 1 per 50 platforms + 1 per 20,000 m² |
| Passenger ships | 2026 | At least 1 per vessel |
| Passenger aircraft | 2026 | At least 1 per aircraft |
| Large places of worship | 2027 | At least 1 per 10,000 m² |
| TOHM and SEM centres | 2027 | At least 1 per centre |
| Fuel stations | 2028 | At least 1 per station |
EXACT COUNT