CALCULATE WITH THE FORMULAS
How many OED devices are required?
Select your facility type and enter a few numbers. The calculator applies the Ministry guide’s formulas to show the minimum device count and deadline.
Minimum number of devices
This number is calculated from the guide’s formulas; it is not legal advice or a definitive compliance finding. Consult the Ministry and competent authorities for implementation.
Minimum number of devices
Fill in the relevant fields to see the result.
Leave your facility details so we can contact you for a needs assessment.
Let us confirm this result togetherThe guide expects the device to be reached within 3 minutes at most. The calculator produces the minimum number from criteria such as area, employees and beds; because of floors, wings, stands, pitches or building layout, more devices may be needed in practice. The exact number is determined by assessing the layout plan and access time together.
FORMÜLLER
Which formula is used?
The table shows the minimum device rules behind the calculator.
| Facility | Phase | Rule |
|---|---|---|
| Shopping malls | 2026 | At least 1 per 10,000 m²; at least 1 below 10,000 m² |
| Event venues | 2026 | At least 1 per 1,000 participants |
| Fitness gyms | 2026 | Single floor: at least 1 · Multi-floor above 2,000 m²: at least 2 |
| Airports | 2026 | At least 1 + 1 per 10,000 m² + at least 1 per floor |
| Workplaces and campuses | 2026 | At least 1 per 1,000 employees; campus area is assessed separately |
| City squares | 2026 | At least 1 per 50,000 m² |
| Hotels and student dormitories | 2026 | 2026: 1 per 500 beds · 2027: at least 1 per facility |
| Rail stations, terminals and trains | 2026 | Terminal: at least 1 + 1 per 10,000 m² + 1 per floor · Train: 1 per train · Station: at least 1 |
| Stadiums and sports venues | 2026 | At least 1 + 1 per 5,000 m² + 1 per 10,000 stadium seats + 1 per stand |
| Intercity bus terminals | 2026 | At least 1 + 1 per 50 platforms + 1 per 20,000 m² |
| Passenger ships | 2026 | At least 1 per vessel |
| Passenger aircraft | 2026 | At least 1 per aircraft |
| Large places of worship | 2027 | At least 1 per 10,000 m² |
| TOHM and SEM centres | 2027 | At least 1 per centre |
| Fuel stations | 2028 | At least 1 per station |
Let us confirm the exact number for your facility.
Share your facility type, area and use; we will assess the scope and device count together.
İLETİŞİM
Let us confirm the result together
Leave your facility details so we can contact you for a needs assessment.
Request a callback
Let us clarify your facility’s scope and the right number of devices. Leave your details and we will get back to you.
5 short fields. Your details are used only for the callback and information.
Your request has been received.
Your details are saved. We will use the number you provided for the callback. In a medical emergency, call 112.